Building components- flat roof - fdrhbi07b
 
 


Cross-section of standard configuration
[Additional views]

Last update10.07.2014/hfa.plb
flat roof: timber frame construction, ventilated, with dry lining

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
  sheet metal roofing or plastic roofing membrane      7800     A1
 24.0 spruce wood closed cladding without spacing of cladding boards  0,130  50  500  1,600   D
 80.0 spruce wood counter battens (ventilation)  0,130  50  500  1,600   D
  sarking membrane sd ≤ 0,3m       1000     E
 15.0 fibreboard (MDF)   0,120  11  600  1,700   D
*   finger-jointed solid construction timber (80/..; e=800)  0,130  50  500  1,600   D
*   Insulation material            
  vapour barrier sd≥ 1m       1000     
 24.0 spruce wood cladding with spacing of cladding boards(24/100); a=400  0,130  50  500  1,600   D
 25.0 gypsum plasterboards with improved properties at high temperatures (fire) (2x12,5 mm) or  0,250  10  800  1,050   A2
 25.0 gypsum fibre board (2x12,5 mm)  0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  E* F* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   200  200  368,0    60  0,21  25,6  adequate  –  49(-3,-8)  3,9  45,0   fdrhbi07b-00  
F = glass wool [0,0040; R=16]
01   220  220  388,0    60  0,19  25,6  adequate  –  49(-2,-7)  5,2  46,3   fdrhbi07b-01  
F = glass wool [0,0040; R=16]
02   240  240  408,0    60  0,18  25,6  adequate  –  50(-3,-8)  6,4  47,6   fdrhbi07b-02  
F = glass wool [0,0040; R=16]
03   200  200  368,0    60  0,19  25,6  adequate  –  50(-2,-7)  29,4  51,1   fdrhbi07b-03  
F = glass wool [0,0035; R=50]
04   200  200  368,0    60  0,21  25,6  adequate  –  49(-2,-7)  6,4  48,1   fdrhbi07b-04  
F = mineral wool [0,038; R=33]
05   200  200  368,0    60  0,21  25,6  adequate  –  50(-3,-8)  -4,7  52,0   fdrhbi07b-05  
F = cellulose fibre [040; E]
06   200  200  368,0    60  0,23  25,6  adequate  –  49(-4,-9)  -5,0  45,0   fdrhbi07b-06  
F = sheep wool [0,041; R=26]