Building components- flat roof - fdrhbi10a
 
 


Cross-section of standard configuration
[Additional views]

Last update13.11.2014/hfa.plb
flat roof: timber frame construction, ventilated, with dry lining

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
  sheet metal roofing or plastic roofing membrane      7800     A1
 24.0 spruce wood closed cladding without spacing of cladding boards  0,130  50  500  1,600   D
 80.0 spruce wood counter battens (ventilation)  0,130  50  500  1,600   D
  sarking membrane sd ≤ 0,3m       1000     E
 15.0 fibreboard (MDF)   0,120  11  600  1,700   D
*   finger-jointed solid construction timber (80/..; e=800)  0,130  50  500  1,600   D
*   Insulation material            
 15.0 OSB (sealed with airtight tape)  0,130  200  650  1,700   D
*   spruce wood cross battens (50/80;a=400)  0,130  50  500  1,600   D
*   Insulation material            
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  E* F* H* I* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   200  200  50  50  396,5    30  0,18  21,7  adequate  –  47(-3,-7)  11,1  47,3   fdrhbi10a-00  
F/I = glass wool [0,0040; R=16]
01   200  200  50    396,5  I=without insulation
 
30  0,21  29,9  adequate  –  45(-3,-7)  8,4  46,7   fdrhbi10a-01  
F = glass wool [0,0040; R=16]
02   220  220  50  50  416,5    30  0,17  21,7  adequate  –  47(-2,-6)  12,4  48,6   fdrhbi10a-02  
F/I = glass wool [0,0040; R=16]
03   240  240  50  50  436,5    30  0,16  21,8  adequate  –  48(-2,-6)  13,6  49,8   fdrhbi10a-03  
F/I = glass wool [0,0040; R=16]
04   200  200  50  50  396,5    30  0,16  21,2  adequate  –  48(-3,-7)  42,3  54,8   fdrhbi10a-04  
F/I = glass wool [0,0035; R=50]
05   200  200  50  50  396,5    30  0,18  21,7  adequate  –  47(-2,-6)  14,2  51,0   fdrhbi10a-05  
F/I = mineral wool [0,038; R=33]
06   200  200  50  50  396,5  null
 
30  0,18  21,7  adequate  –  46(-2,-6)  0,6  55,9   fdrhbi10a-06  
F = cellulose fibre [040; E]
07   200  200  50  50  396,5    30  0,20  22,3  adequate  –  46(-3,-7)  0,2  47,3   fdrhbi10a-07  
F/I = sheep wool [0,041; R=26]